Coalator = Separator + Coalescer

In a Coalator, the mechanical separation takes place just before the air/gas stream flows through the coalescing media. The coalescing element is open to the separation chamber, allowing condensate to fall, thus preventing re-entrainment. The separation chamber also doubles as a condensate accumulator.

Benefits:

  1. Higher overall efficiency. Coalescer's exposure to condensed fluids is virtually eliminated.
  2. Large condensate holding chamber provides extra protection to coalescer.
  3. Easier installation -additional separator and drain are not required.
  4. Lowest overall cost -saves on equipment and installation costs.

Specifications and Dimensions

Model SCFM Port size
- in (mm)
Dimensions - in (mm) Approx.
ship wt.
lb (kg)
A B C D E F
CR25D 25 1/2 (12.7) NPT 4 (101.6) 8 (203.2) 3 (76.2) 3 1/4 (82.6) 1 3/4 (44.5) 4 1/2 (114.3) 6 (2.7)
CR35D 35 1/2 (12.7) NPT 4 (101.6) 8 (203.2) 3 (76.2) 3 1/4 (82.6) 1 3/4 (44.5) 4 1/2 (114.3) 6 (2.7)
CR60D 60 1/2 (12.7) NPT 4 (101.6) 10 1/2 (266.7) 3 (76.2) 3 1/4 (82.6) 1 3/4 (44.5) 7 (177.8) 8 (3.6)
CR115D 115 1 (25.4) NPT 5 1/4 (133.35) 13 1/2 (342.9) 4 (101.6) 4 (101.6) 2 (50.8) 8 7/8 (225.43) 4.5 (2.04)
CR155D 155 1 1/2 (38.1) NPT 5 1/4 (133.35) 16 1/2 (419.1) 4 (101.6) 4 (101.6) 2 (50.8) 11 7/8 (301.63) 6.5 (2.95)
CR250D 250 1 1/2 (38.1) NPT 5 1/4 (133.35) 19 1/4 (488.95) 4 (101.6) 4 (101.6) 2 (50.8) 14 7/8 (377.83) 17 (7.71)
CR350D 350 2 (50.8) NPT 7 3/4 (196.85) 26 1/2 (673.1) 5 1/2 (139.7) 6 (152.4) 2 1/2 (63.5) 21 (533.4) 20 (9.07)
CR450D 450 2 1/2 (63.5) NPT 7 3/4 (196.85) 26 3/4 (679.45) 5 1/2 (139.7) 6 (152.4) 2 1/2 (63.5) 21 1/4 (539.75) 35 (15.88)
CR600D 600 2 1/2 (63.5) NPT 7 3/4 (196.85) 31 1/2 (800.1) 5 1/2 (139.7) 6 (152.4) 2 1/2 (63.5) 26 (660.4) 42 (19.05)
CR800D 800 3 (76.2) NPT 7 3/4 (196.85) 37 1/2 (952.5) 7 1/2 (190.5) 6 (152.4) 3 1/2 (88.9) 30 (762) 47 (21.32)
CR1050D 1050 3 (76.2) NPT 7 3/4 (196.85) 38 (965.2) 7 1/2 (190.5) 6 (152.4) 3 1/2 (88.9) 30 1/2 (774.7) 58 (26.31)
CR1250D 1250 3 (76.2) FLG 7 3/4 (196.85) 44 (1117.6) 7 1/2 (190.5) 6 (152.4) 3 1/2 (88.9) 36 1/2 (927.1) 70 (31.75)

Notes:

  1. @100 PSIG (6.9 Bar G) and 225°F (107°C)
  2. Filters come with initial element(s)
  3. 'D' indicates differential pressure gauge

Maximum Operating Pressure: 150 PSIG (10.35 Bar G)

Coalator Recommended Specifications

The Pioneer Coalator shall be constructed of a heavy duty steel vessel, internally coated for rust prevention. It shall incorporate a multi-step impingement separator and a high efficiency microfiber coalescer. The coalescing element shall be open to the separation chamber, allowing condensate to fall, thus preventing re-entrainment. The coalator shall have a removable top for easy element replacement. The coalator shall include a differential pressure indicator to signal element change. The coalator shall be Pioneer Model_____


 

÷Pioneer Air Systems, Inc.÷

÷210 Flatfork Rd. ÷Wartburg, TN 37887÷Tel: 800-264-1AIR÷Fax: 423-346-3865 ÷ sales@pioneerair.com ÷

Copyright (c) 2004 - Pioneer Air Systems, Pioneer Engineering. All rights reserved.
Information in this document is subject to change without notice.