In a Coalator, the mechanical
separation takes place just before the air/gas stream flows through
the coalescing media. The coalescing element is open to the
separation chamber, allowing condensate to fall, thus preventing
re-entrainment. The separation chamber also doubles as a condensate
accumulator.
Benefits:
|
![]() |
| Model | SCFM | Port size - in (mm) |
Dimensions - in (mm) | Approx.
ship wt. lb (kg) |
|||||
| A | B | C | D | E | F | ||||
| CR25D | 25 | 1/2 (12.7) NPT | 4 (101.6) | 8 (203.2) | 3 (76.2) | 3 1/4 (82.6) | 1 3/4 (44.5) | 4 1/2 (114.3) | 6 (2.7) |
| CR35D | 35 | 1/2 (12.7) NPT | 4 (101.6) | 8 (203.2) | 3 (76.2) | 3 1/4 (82.6) | 1 3/4 (44.5) | 4 1/2 (114.3) | 6 (2.7) |
| CR60D | 60 | 1/2 (12.7) NPT | 4 (101.6) | 10 1/2 (266.7) | 3 (76.2) | 3 1/4 (82.6) | 1 3/4 (44.5) | 7 (177.8) | 8 (3.6) |
| CR115D | 115 | 1 (25.4) NPT | 5 1/4 (133.35) | 13 1/2 (342.9) | 4 (101.6) | 4 (101.6) | 2 (50.8) | 8 7/8 (225.43) | 4.5 (2.04) |
| CR155D | 155 | 1 1/2 (38.1) NPT | 5 1/4 (133.35) | 16 1/2 (419.1) | 4 (101.6) | 4 (101.6) | 2 (50.8) | 11 7/8 (301.63) | 6.5 (2.95) |
| CR250D | 250 | 1 1/2 (38.1) NPT | 5 1/4 (133.35) | 19 1/4 (488.95) | 4 (101.6) | 4 (101.6) | 2 (50.8) | 14 7/8 (377.83) | 17 (7.71) |
| CR350D | 350 | 2 (50.8) NPT | 7 3/4 (196.85) | 26 1/2 (673.1) | 5 1/2 (139.7) | 6 (152.4) | 2 1/2 (63.5) | 21 (533.4) | 20 (9.07) |
| CR450D | 450 | 2 1/2 (63.5) NPT | 7 3/4 (196.85) | 26 3/4 (679.45) | 5 1/2 (139.7) | 6 (152.4) | 2 1/2 (63.5) | 21 1/4 (539.75) | 35 (15.88) |
| CR600D | 600 | 2 1/2 (63.5) NPT | 7 3/4 (196.85) | 31 1/2 (800.1) | 5 1/2 (139.7) | 6 (152.4) | 2 1/2 (63.5) | 26 (660.4) | 42 (19.05) |
| CR800D | 800 | 3 (76.2) NPT | 7 3/4 (196.85) | 37 1/2 (952.5) | 7 1/2 (190.5) | 6 (152.4) | 3 1/2 (88.9) | 30 (762) | 47 (21.32) |
| CR1050D | 1050 | 3 (76.2) NPT | 7 3/4 (196.85) | 38 (965.2) | 7 1/2 (190.5) | 6 (152.4) | 3 1/2 (88.9) | 30 1/2 (774.7) | 58 (26.31) |
| CR1250D | 1250 | 3 (76.2) FLG | 7 3/4 (196.85) | 44 (1117.6) | 7 1/2 (190.5) | 6 (152.4) | 3 1/2 (88.9) | 36 1/2 (927.1) | 70 (31.75) |
Notes:
Maximum Operating Pressure: 150 PSIG (10.35 Bar G)
Coalator Recommended Specifications
The Pioneer Coalator shall be constructed of a heavy duty steel vessel, internally coated for rust prevention. It shall incorporate a multi-step impingement separator and a high efficiency microfiber coalescer. The coalescing element shall be open to the separation chamber, allowing condensate to fall, thus preventing re-entrainment. The coalator shall have a removable top for easy element replacement. The coalator shall include a differential pressure indicator to signal element change. The coalator shall be Pioneer Model_____
÷Pioneer Air Systems, Inc.÷
÷210 Flatfork Rd. ÷Wartburg, TN 37887÷Tel: 800-264-1AIR÷Fax: 423-346-3865 ÷ sales@pioneerair.com ÷
Copyright (c) 2004 - Pioneer Air Systems,
Pioneer Engineering. All rights reserved.
Information in this document is subject to change without notice.