SHL Specifications

The twin tower compressed air dryer shall be capable of drying ______SCFM/NM³ of air at 100 PSIG/6.9 BAR G and 100°F/37.8°C inlet conditions down to -40°F/-40° C PDP on a continuous and automatic basis. The vessels over 6"/152mm diameter shall be ASME coded. Each vessel shall have ______lbs/kg of high performance desiccant. Each vessel shall have its own pressure relief valve rated for the dryer capacity*. The inlet valves shall be full port opening, air actuated, and non-lube*. The inlet valves shall be serviceable without having to remove the dryer piping*. A four-way solenoid valve shall control air flow. The purge exhaust valve(s) shall be of solenoid type. To reduce noise the dryer shall have two mufflers. The timing cycle shall be five minutes To prevent desiccant bumping, the air flow shall be downflow and the regenerating vessel shall be repressurized before switching of air flow. The control panel and wiring shall be NEMA 1. Controls shall include solid state timing circuit, power on switch, and indicator. The dryer shall have a 10-year limited warranty.

*SHL35 and up

The dryer shall be PIONEER model SHL_______.

Options:

Prefilter____________________ Afterfilter___________________Alternate: Best Aire (filters and bypass):

o Economy o Silver o Gold o Diamond o Carbon Adsorber-Alert o Micro-Coalescer o Demand Cycle o Dew Point Meter


SHL Series Specifications
  Inlet Capacity* in SCFM/NM³HR °F/°C PDP Dimensions (ins/mm) Inlet/ outlet ins. NPT Approximate Weight (lbs /kg)
Model -100/-73 -40/-40 20/-7 L W H Dessicant Shipping
SHL5 3/5 5/9 8/14 12/305 6.5/165 20/508 1/4 5/2.3 50/23
SHL10 6/10 10/17 15/25 12/305 6.5/165 20/508 1/4 7/3.2 60/27
SHL15 9/15 15/25 20/34 20/508 6.5/165 20/508 3/8 15/6.8 80/36
SHL20 12/20 20/34 30/51 20/508 9/229 24/610 1/2 24/11 100/46
SHL25 15/25 25/43 35/60 20/508 9/229 24/610 1/2 26/12 120/50
SHL35 20/34 35/60 50/85 33/838 13/330 52/1321 3/4 36/17 320/145
SHL50 30/51 50/85 70/119 33/838 13/330 64/1626 3/4 56/26 346/147
SHL75 45/77 75/128 100/170 33/838 13/330 79/2007 1 80/36 395/179
SHL100 60/102 100/170 150/255 41/1041 19/482 72/1829 1 110/50 575/261
SHL150 90/153 150/255 200/340 41/1041 19/483 72/1829 1 1/2 165/75 675/306
SHL200 120/204 200/340 300/510 41/1041 19/483 72/1829 1 1/2 200/91 750/340

Notes:

  1. At 100°F/37.8°C, 100 PSIG/6.9 BAR G inlet
  2. Desiccant is factory filled
  3. -40°F/-40°C PDP is standard; notify factory for required PDP
  4. Standard voltage 115/1/60; nonstandard available
  5. Cycle time 5 minutes
  6. Models SHL5 through 25 are wall mount
  7. NEMA 1 electrical
  8. Maximum pressure 150 PSIG/10.35 BAR G

 